Case study: Greenhouse irrigation system design

A California greenhouse grower grants extension agents full access to review his irrigation system design and function. See what lessons you can learn from this in-depth tour.

Editor's Note: This article originally appeared in the April 2026 print edition of Greenhouse Management under the headline “Peer-to-peer review.”

Figure 1. William’s hanging baskets.
Photos courtesy of the authors

In 2025, we visited a greenhouse in San Diego, California, growing flowering tropicals and houseplants on benches and in hanging baskets. William (using his first name only for anonymity) is the head grower who kindly showed us around and agreed to let us write a case study based on his experiences.

During our visit, he gave us some data about his irrigation design and management. In this article, we will discuss what William is doing well, what could be improved and what you can learn from him for your own operation. We hope you will benefit from this analysis to improve your irrigation practices.

Irrigation system and irrigation scheduling setup

Let’s consider the irrigation system that William uses for the hanging baskets (Figure 1). Each irrigation lateral is a ½-inch polyethylene line, 85 feet long with 127 drippers spaced by 8 inches that serve 127 plants. Plants are spaced roughly 1 foot center-to-center on the line and 1 foot on average between lines.

The drippers are Netafim pressure compensating grey WPCJ with 1.06 gph flow rate. The drippers are inserted onto the polyethylene line, and a spaghetti tubing takes water from the dripper to a drip stake inserted into each plant. The beginning of each lateral line carries (127×1.06) = 134 gph or 2.25 gpm.

William irrigates for three minutes twice a day, three times per week (or four times per week when the weather is particularly hot). Thus, his weekly run time ranges from 18 to 24 minutes per week. William’s plant containers have a top diameter of 6 inches and a volume of 44 fluid ounces (1,300 mL). We will discuss these data in part two of this series.

Is William doing a good job managing irrigation? If you are a greenhouse grower, you’re likely able to use the data above to answer this question. Try to give your answer before reading on.

Figure 2. A pressure regulator is installed at the beginning of each lateral line in a greenhouse.

Are the irrigation laterals well designed? Are the pressure-compensating emitters appropriate in this situation?

Irrigation lines must be designed to achieve pressure uniformity, which results in uniformity in the volumes of water distributed to each plant. Pressure always drops as water flows in a pipe or polyethylene line. This may create a problem in which emitters at the end of the lateral, or laterals at the end of the mainline, may receive less pressure than the ones at the beginning.

Similarly, irrigation blocks close to the water source may receive a lot more pressure than those far away. With this in mind, mainlines are sized to lose only an acceptable amount of pressure. The acceptable amount of pressure loss between blocks is determined by the operating pressure range of the emitters and by the amount of irrigation unevenness (lack of uniformity) that a grower can tolerate.

First, let’s discuss pressure loss and the causes of it in irrigation systems. The loss of pressure in irrigation systems can be due to a few things. These include elevation changes, valves and other equipment in the lines, but most importantly pressure loss is due to the friction of flowing water against the sidewalls of the pipe or line. The variables that determine pressure loss by friction in a section of pipe are its length, its diameter and the flow rate of the water (gallons per minute).

As the water moves through the pipes, friction against the sidewalls creates turbulence, which decreases pressure. Pressure loss is twice as much if the pipe is twice as long, and it becomes 3.5 times larger if the flow rate is doubled.

However, a larger pipe diameter gives a smaller pressure loss, all other things being equal. Doubling the diameter decreases the pressure loss almost 30 times! This is because proportionally speaking, there is less perimeter of wall per cross-sectional area of water, which would decrease friction.

A well-designed system will have lateral lines that supply each irrigation emitter with the same pressure, whether they are at the beginning or at the end of the line. Complicating the issue in the laterals, flow rate decreases as water moves farther down the line, since each emitter is discharging water.

Using the Hazen-Williams equation, we calculated that the pressure loss across the ½-inch lateral line, 85 feet long with 127 outlets and a flow rate of 2.25 gpm, is 2.2 psi. Note that this equation is calculated for William’s polyethylene laterals. Other materials have different roughness coefficients.

Figure 3. Pressure compensating 0.53 gph emitters installed in a cut flower greenhouse.

Does William need pressure compensating emitters?

Not really. The pressure difference from the beginning to the end of the lateral is relatively small. This is because the lateral is not very long, the number of plants is not large and flow rate of the drippers is relatively small. These determine a total flow rate in the polyethylene line of only 2.25 gpm.

Length and flow rate are so small that William can get away with installing a small diameter line (half-inch) without suffering large pressure losses across it. For this reason, there would be little difference in irrigation volume produced by the first emitter of the line that is exposed to 2.2 psi more than the last.

Notice that this is a pressure difference, not an absolute pressure. These Netafim WPCJ operate at 10.2 to 58 psi. If operated in this range of pressures, they will produce the same flow rate. Instead, non-pressure compensating drip emitters generally need an operating pressure of about 10 psi, and they will produce more flow rate the more pressure they are exposed to.

William could use non-pressure compensating emitters and design the mainline so that the pressure at the beginning of the lateral is 12.2 psi, and at the end of the lateral it will be 10 psi.

Pressure losses by friction that happen through the polyethylene lateral also happen as water travels in the PVC mainline that serves each lateral. As a result, the last lateral served by the mainline will receive a lower pressure than the first. Let’s say that the mainline was designed so that the last lateral receives 12.2 psi; then the first lateral will be exposed to a higher pressure.

Just like we did for the lateral, one could calculate the pressure loss across the mainline using the Hazen-Williams equation. Let’s say that by doing so, we calculate a pressure loss of 22.8 psi. That means the first polyethylene lateral must receive 35 psi. In this case, pressure compensating emitters are useful, because the first emitter on the first lateral will run at 35 psi and the last emitter at 32.8 psi. They are both within the pressure compensating range of the WPCJ.

Another solution to this problem is installing pressure regulators at the beginning of each lateral (Figure 2). These devices drop pressure to a determined level. If each of William’s polyethylene laterals had a 12-psi pressure regulator, then the first emitter on the lateral would run at 12 psi and the last one at 9.8 psi. Those are both acceptable, even for non-pressure compensating emitters.

Now, let’s say that William’s line was 300 feet instead of 85 feet. Do pressure compensating emitters make sense in this scenario?

Again, using the Hazen-Williams equation, we calculated that a ½-inch diameter, 300-feet long polyethylene line with 2.25 gpm at the beginning and 127 outlets loses 8.5 psi across it. Now, with a pressure loss of 8.5 psi, William couldn’t use non-pressure compensating emitters anymore, since the pressure would be either too high at the beginning or too low at the end of his polyethylene lateral.

As you can see, with longer runs, pressure compensating emitters become useful. William could design the mainline so the last polyethylene lateral has 19 psi at the beginning and 10.5 psi at the end to stay in the range of pressure compensation of the emitters. As long as the pressure at the beginning of the first polyethylene lateral is not higher than 58 psi, then the pressure compensating emitters would do their job well.

A similar case could be made if William was using 2 gph or 4 gph emitters or if he had 350 plants per line instead of 127. The pressure losses across the lateral would be 7 psi, 25 psi and 14 psi respectively, all other variables being equal. Just like a longer length, a larger flow rate in the polyethylene line would increase friction and make the pressure loss across it larger. Again, this scenario would justify the use of pressure compensating emitters.

Button pressure compensating emitters cost between $0.25 and $0.50 depending on brand and model, and they have become much more affordable in recent years. They are now only slightly more expensive than equivalent non-pressure compensating emitters, so by all means, we recommend using them. Also, they become cheaper if you buy large quantities.

The only possible downside is that pressure compensating emitters may require finer filtering (120 to 150 mesh) and may clog more easily than non-pressure compensating ones with larger orifices.

Another approach that William could have used to irrigate uniformly is to save money on the emitters (by buying non-pressure compensating ones) and to invest instead in larger diameter polyethylene laterals. Pressure loss across the laterals would have been a lot less if William had installed lateral polyethylene lines with a larger diameter.

Using the same equation, we calculated that the pressure drop across the 85 feet of line would have been 0.3 psi with a ¾-inch inside diameter line and only 0.1 psi with a 1-inch inside diameter line. Similarly, William could have installed a larger PVC mainline so the pressure difference at the beginning of each lateral polyethylene lateral would have been minimized.

This way, he would have spent more on a larger diameter pipe, but he would have saved on both pressure regulators and pressure compensating emitters.

Finally, we often see unexpected fluctuations in pressure in nurseries and greenhouses. Since the species grown, cycles, production schedules and techniques are so diverse, it’s often difficult to maintain strict irrigation schedules. While nothing can protect you from drops in pressure (except maybe a variable frequency drive pump), pressure regulators and pressure compensating emitters are good “insurance policies” against unanticipated spikes in pressure (Figure 3).

The variability of pressure is also a reason why we recommend buying a handheld pressure gauge for each of your irrigators and installing Schrader valves to measure pressure at each block valve and at the end of each polyethylene line.

In conclusion, William’s irrigation system is well-designed, and it probably delivers high distribution uniformity. Pressure compensating emitters are a good choice for a variety of reasons, although larger pipe sizing and/or pressure regulators may achieve the same level of uniformity.

In part two of this series, publishing in the May 2026 issue of Greenhouse Management, we will discuss William’s irrigation scheduling practices and talk about substrates’ physical properties, evapotranspiration, distribution uniformity and leaching fraction.

Gerry Spinelli is the production horticulture adviser for nurseries, floriculture and CEA at the University of California Cooperative Extension San Diego. Andrew Ristvey is the extension specialist for commercial horticulture at the University of Maryland. Contact them at gspinelli@ucdavis.edu and aristvey@umd.edu.